Click! 511 Bid Specication
1.0 General. This item shall govern the purchase and installa-
tion of a digital I/O repeater module (DRM) equivalent to the
Wavetronix Click!™ 511. Test results and other documentation
demonstrating performance and capabilities shall be pro-
vided.
2.0 Product Description. The DRM shall be used to monitor
distributed digital outputs with serial devices, such as the
Wavetronix SmartSensor™. The DRM shall be used in either
server mode or client mode, where clients are used to send
information to the server. The DRM shall convert 2-wire half-
duplex RS-485 to half-duplex RS-232 and vice versa.
3.0 Physical. The DRM shall not exceed 0.29 lbs. (0.1 kg) in
weight.
The DRM shall not exceed 4.5 in. × 4 in. × 0.9 in. (11.4 cm x 10.2
cm x 2.3 cm) in its physical dimensions.
The DRM shall operate in the temperature range of -29°F to
165°F (-34°C to 74°C).
4.0 Mounting. The DRM shall mount to a DIN rail with hot-
swappable power and communication buses for quick installa-
tion and replacement.
5.0 Power. The DRM shall operate using less than 0.8 W of
average power at 10 VDC to 30 VDC.
6.0 Connections. The DRM shall include the following con-
nections for power and communication:
6.1 Power. The DRM shall include a 5-position connector,
with two contact points reserved for connecting power
through the bus.
The DRM shall supply voltage input monitoring with set-
table thresholds of 11.7 or 22.7 VDC.
6.2 Serial Ports. The DRM shall include the following
four independent physical serial ports:
● RS-232front:DB-9femaleDCEconnectorwithDIP
switch override to select between programming and
run mode
● RS-485top:5-positionconnectorforconnectingfrom
T-bus
● RS-232top:Pluggablescrewterminal
● RS-485top:PluggablescrewterminalandanRJ-11jack
6.3DigitalInputPorts.TheDRMshallincludetwomulti-
function digital input ports with the following features:
● Low-levelACinputmonitoringviaclamp-onsplit-core
currenttransformerswith1W120VACloadthreshold
suitableformonitoringincandescentorLEDsignal
indication status
● Contactclosureinputmonitoringcircuitthatalso
serves to monitor low-level DC logic with a threshold of
2.5 V
● DCvoltageinputmonitoringwithselectablethresholds
of 9, 11.7 and 23.4 VDC
● Maximuminputeventfrequencyof250Hz
6.4 Contact Closure Output Ports. The DRM shall feature
twosolidstatecontactclosureoutputportswith250Hz
of output signaling capability.
7.0 Communication. The DRM shall have the following com-
munication capabilities:
7.1 Serial Protocol Conversion. The DRM shall allow
communications with any serial device that has a serial
connection by converting 3-wire half-duplex RS-485 com-
munication to half-duplex RS-232 communication, and
vice versa.
8.0 Baud Rate. The DRM shall operate at a baud rate of 9600
bps.
9.0 Conguration Features. The DRM shall have a push-but-
ton on the faceplate of the unit that:
● SetstheDRMtoservermode
● SetstheDRMtoclientmode
● Selectsserveroutput
● ResetstoDRMfactorydefaults
ThefrontoftheDRMshallincludearedpowerLED,aswell
asgreenandyellowTXandRXLEDsthatshallilluminate
whencorrespondingdataissuccessfullytransmiedorre-
ceived.
TheseLEDs,aswellastheblueLEDnexttothem,shallalso
act as operation mode indicators for operation modes selected
withthepush-buon.
TheDRMshallincludetwobanksofLEDs,oneyellowand
one red, that display submenu selections and application
information.
10.0 Upgrade Utility Software. The DRM shall be upgraded
using software that:
● RunsonaWindowsdesktoporlaptopPC(Windows2000
and newer)
● CanupgradetheDRMfirmwaretoaddnewfeaturestothe
DRM